HART |
PROFIBUS PA or Foundation fieldbus |
Input |
|
Measured variable |
Absolute pressure |
Spans (infinitely adjustable) or nominal measuring range and max. permissible operating pressure |
Span |
Maximum operating pressure |
Nominal measuring range |
Maximum operating pressure |
|
8.3 ... 250 mbar a (0.12 ... 3.6 psi a) |
32 bar a (464 psi a) |
250 mbar a (3.6 psi a) |
32 bar a (464 psi a) |
|
43 ... 1300 mbar a (0.62 ... 18.9 psi a) |
32 bar a (464 psi a) |
1300 bar a (18.9 psi a) |
32 bar a (464 psi a) |
|
160 ... 5000 mbar a (2.32 ... 72.5 psi a) |
32 bar a (464 psi a) |
5 bar a (72.5 psi a) |
32 bar a (464 psi a) |
|
1 ... 30 bar a (14.5 ... 435 psi a) |
160 bar a (2320 psi a) |
30 bar a (435 psi a) |
160 bar a (2320 psi a) |
|
5.3 ... 100 bar a (76.9 ... 1450 psi a) |
160 bar a (2320 psi a) (for connection thread M10 and 7/16-20 UNF in the process flanges) |
100 bar a (1450 psi a) |
160 bar a (2320 psi a) (for connection thread M10 and 7/16-20 UNF in the process flanges) |
Lower measuring limit |
|
|
- Measuring cell with silicone oil filling
|
0 mbar a (0 psi a) |
Upper measuring limit |
100% of max. span |
Output |
|
|
Output signal |
4 ... 20 mA |
Digital PROFIBUS PA or Foundation fieldbus signal |
- Lower limit (infinitely adjustable)
|
3.55 mA, factory preset to 3.84 mA |
- |
- Upper limit (infinitely adjustable)
|
23 mA, factory preset to 20.5 mA or optionally set to 22.0 mA |
- |
Load |
|
- Without HART communication
|
R B ≤ (UH - 10.5 V)/0.023 A in Ω, UH : Power supply in V |
- |
|
R B = 230 ... 500 Ω (SIMATIC PDM) or RB = 230 ... 1100 Ω (HART Communicator) |
- |
Physical bus |
- |
IEC 61158-2 |
With polarity reversal protection |
- |
Yes |
Measuring accuracy |
Acc. to EN 60770-1 |
Reference conditions (All error data refer always refer to the set span) |
Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 °C (77 °F)) r: Span ratio (r = max. span / set span) |
Error in measurement and fixed-point setting (including hysteresis and repeatability) |
|
|
|
≤ 0.1 % |
|
≤ 0.1 % |
|
|
≤ 0.2 % |
|
Long-term drift (temperature change ±30 °C (±54 °F)) |
≤ (0.1 · r)%/year |
≤ 0.1 %/year |
Influence of ambient temperature |
|
- at -10 ... +60 °C (14 ... 140 °F)
|
≤ (0.1 · r + 0.2)% |
≤ 0.3 % |
- at -40 ... -10 °C and +60 ... +85 °C
(-40 ... +14 °F and 140 ... 185 °F) |
≤ (0.1·r + 0.15) %/10 K |
≤ 0.25 %/10 K |
Measured Value Resolution |
- |
3 · 10-5 of nominal measuring range |
Conditions of use |
|
Degree of protection (to EN 60529) |
IP65 |
Temperature of medium |
|
- Measuring cell with silicone oil filling
|
-40 ... +100 °C (-40 ... +212 °F) |
- Measuring cell with inert filling liquid
|
-20 ... +100 °C (-4 ... +212 °F) |
- In conjunction with dust explosion protection
|
-20 ... +60 °C (-4 ... +140 °F) |
Ambient conditions |
|
|
|
|
-30 ... +85 °C (-22 ... +185 °F) |
|
-50 ... +85 °C (-58 ... +185 °F) |
|
|
|
Permissible |
- Electromagnetic Compatibility
|
|
|
Acc. to EN 50081-1 |
|
Acc. to EN 61326 and NAMUR NE 21 |
Design |
|
Weight (without options) |
≈ 4.5 kg (≈ 9.9 lb) |
Enclosure material |
Low-copper die-cast aluminum, GD-AlSi 12 or stainless steel precision casting, Mat. No. 1.4408 |
Wetted parts materials |
|
|
Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819, Monel, mat. No. 2.4360, tantalum or gold |
- Process flanges and sealing screw
|
Stainless steel, mat. No. 1.4408, Hastelloy C4, mat. No. 2.4610 or Monel, mat. No. 2.4360 |
|
FPM (Viton) or optionally: PTFE, FEP, FEPM and NBR |
Measuring cell filling |
Silicone oil or inert filling liquid (max. 160 bar (2320 psi a) with oxygen measurement) |
Process connection |
¼-18 NPT and flange connection with mounting thread M10 to DIN 19213 or 7/16-20 UNF to EN 61518 |
Material of mounting bracket |
|
|
Sheet-steel, Mat. No. 1.0330, chrome-plated |
|
Sheet stainless steel, mat. No. 1.4301 (SS 304) |
Power supply U H |
|
Supplied through bus |
Terminal voltage on transmitter |
10.5 ... 45 V DC 10.5 ... 30 V DC in intrinsically-safe mode |
- |
Separate 24 V power supply necessary |
- |
No |
Bus voltage |
|
|
- |
9 ...32 V |
- With intrinsically-safe operation
|
- |
9 ...24 V |
Current consumption |
|
|
- |
12.5 mA |
- Startup current ≤ basic current
|
- |
Yes |
- Max. current in event of fault
|
- |
15.5 mA |
Fault disconnection electronics (FDE) available |
- |
Yes |
Certificates and approvals |
|
|
Classification according to PED 97/23/EC |
For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) |
Explosion protection |
|
|
PTB 99 ATEX 2122 |
|
Ex II 1/2 G EEx ia/ib IIB/IIC T6 |
- Permissible ambient temperature
|
-40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +70 °C (-40 ... +158 °F) temperature class T5; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 |
|
To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW; Ri = 300 Ω |
FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W
Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W |
- Effective internal inductance/capacitance
|
L i = 0.4 mH, Ci = 6 nF |
L i = 7 μH, Ci = 1.1 nF |
|
PTB 99 ATEX 1160 |
|
Ex II 1/2 G EEx d IIC T4/T6 |
- Permissible ambient temperature
|
-40 ... +85 °C (-40 ... +185 °F) temperature class T4; -40 ... +60 °C (-40 ... +140 °F) temperature class T6 |
|
To circuits with values: UH = 10.5 ... 45 V DC |
To circuits with values: UH = 9 ... 32 V DC |
- Dust explosion protection for zone 20
|
PTB 01 ATEX 2055 |
|
Ex II 1 D IP65 T 120 °C Ex II 1/2 D IP65 T 120 °C |
- Permissible ambient temperature
|
-40 ... +85 °C (-40 ... +185 °F) |
|
120 °C (248 °F) |
|
To certified intrinsically-safe circuits with maximum values: Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 Ω |
FISCO supply unit: Uo = 17.5 V, Io = 380 mA, Po = 5.32 W
Linear barrier: Uo = 24 V, Io = 250 mA, Po = 1.2 W |
- Effective internal inductance/capacitance
|
L i = 0.4 mH, Ci = 6 nF |
L i = 7 μH, Ci = 1.1 nF |
- Dust explosion protection for zone 21/22
|
PTB 01 ATEX 2055 |
|
Ex II 2 D IP65 T 120 °C |
|
To circuits with values: UH = 10.5 ... 45 V DC; Pmax = 1.2 W |
To circuits with values: UH = 9 ... 32 V DC; Pmax = 1.2 W |
- Type of protection "n" (zone 2)
|
TÜV 01 ATEX 1696 X |
Planned |
|
Ex II 3 G EEx nA L IIC T4/T5/T6 |
- |
- Explosion protection acc. to FM
|
Certificate of Compliance 3008490 |
- Identification (XP/DIP) or (IS); (NI)
|
CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III |
- Explosion protection to CSA
|
Certificate of Compliance 1153651 |
- Identification (XP/DIP) or (IS)
|
CL I, DIV 1, GP ABCD T4...T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III |