SITRANS P pressure transmitters, ZD series |
|
Mode of operation |
|
Measuring principle |
Thin-film strain gauge |
Input |
|
Measured variable |
Gage and absolute pressure |
Measured range |
Resolution |
0 ... 2 bar (0 ... 29 psi) |
0.6 mbar (0.008 psi) |
0 ... 10 bar (0 ... 145 psi) |
3 mbar (0.044 psi) |
0 ... 50 bar (0 ... 725 psi) |
15 mbar (0.218 psi) |
0 ... 200 bar (0 ... 2900 psi) |
60 mbar (0.9 psi) |
0 ... 400 bar (0 ... 5802 psi) |
120 mbar (1.8 psi) |
Measured range |
Overload limit |
0 ... 2 bar (0 ... 29 psi) |
5 bar (72.5 psi) |
0 ... 10 bar (0 ... 145 psi) |
25 bar (363 psi) |
0 ... 50 bar (0 ... 725 psi) |
120 bar (1740 psi) |
0 ... 200 bar (0 ... 2900 psi) |
500 bar (7250 psi) |
0 ... 400 bar (0 ... 5802 psi) |
600 bar (8700 psi) |
Range adjustment (turndown) |
5:1 (max. 10:1) |
Output |
|
Output signal |
4 ... 20 mA |
Lower current limit |
min. 3.6 mA |
Upper current limit |
max. 23 mA |
Output protected against |
Reversed polarity, overvoltage and short-circuiting |
Max. load |
R B = (UH - 12 V) / 0.023 A |
Voltage measurement |
Linear rising |
Measuring accuracy |
To EN 60770-1 |
Error in measurement (including non-linearity, hysteresis and repeatability, at 25 °C (77 °F)) |
< 0.25 % of full-scale value (typical), max. 0.5 % |
Adjustment time |
< 100 ms |
Long-term drift |
0.25 % of full scale value/year |
Influence of ambient temperature |
|
|
< ±0.25 %/10 K of full-scale value |
|
±0.5 %/10 K of full-scale value |
Vibration influence |
0.05 %/g to 500 Hz in all directions (to IEC 68‑2‑64) |
Power supply effect |
< ±0.01 %/V of full-scale value |
Rated conditions |
|
Ambient conditions |
|
|
-25 ... +85 °C (-13 ... +185 °F) |
- Temperature for best readability
|
-10 ... +70 °C (14 ... 158 °F) |
|
-40 ... +85 °C (-40 ... +185 °F) |
Medium conditions |
|
|
-30 ... +100 °C (-22 ... +212 °F) |
Degree of protection |
IP65 to EN 60529 |
Electromagnetic compatibility |
|
- Emitted interference and noise immunity
|
To EN 61 326/A1 appendix A (1998) |
Displays and controls |
|
Display |
LCD, max. 5 digits, digit height 9 mm |
Decimal point |
Freely parameterizable |
Limit values |
Freely parameterizable |
Limit violation display |
Red LED and message on LCD (↑symbol /↓symbol in case of limit violation in upward / downward direction) |
Parameterization |
With 3 keys |
Units |
mA or % or physical variable (default setting: bar)
Other dimensions: mbar, kPa, MPa, mmH20, mH20, psi, inH20, mmHg, kg/cm², torr, atm |
Damping |
Between 0.1 and 100 s
(increment: 0.1 s) freely parameterizable |
Design |
|
Weight |
≈0.6 kg (≈1.32 lb) |
Electrical connection |
Using 2-pole plug connector with M16x1.5‑Cable inlet to EN 175301‑803A, plastic |
Process connection |
- Male thread G½B and female thread G1/8B
- G½B to EN 837-1
- Female thread: ½-14 NPT
|
Version of housing/process connection |
- Radial (type A), can be swiveled by max. ±120° (α)
|
|
- Axial (type B), can be swiveled by max. ±360°
|
Material |
|
Non-wetted parts materials |
|
|
∅ 80 mm (3.15 inch), stainless steel mat. No. 1.4016 |
|
Stainless steel, mat. No. 1.4016 with glass |
Wetted parts materials |
|
|
Al2O3 |
|
Viton |
|
Stainless steel, mat. No. 1.4571/316Ti |
Power supply |
|
Terminal voltage on pressure transmitter (UH) |
12 ... 30 V DC |
Certificate and approvals |
|
Classification according to pressure equipment directive 97/23/EC |
For gases of fluid group 1 and liquids of fluid 1; complies with requirements of article 3, paragraph 3 (sound engineering practice) |