Pressure transmitters for food, pharmaceuticals and biotechnology |
Mode of operation |
|
Measuring principle |
Piezo-resistive |
Input |
|
Measured variable |
Gage or absolute pressure |
Measuring range |
0 ... 160 mbar (0 ... 2.32 psi) ... 0 ... 40 bar (0 ... 580 psi) |
Output |
|
Output signal |
|
|
4 ... 20 mA |
|
0 ... 20 mA |
Measuring accuracy |
to EN 60770-1 |
Linearity error including hysteresis (reference point adjustment) |
= 0.2 % of full-scale value |
Adjustment accuracy |
= ± 0.2 % of full-scale value |
Response time |
< 20 ms |
Influence of ambient temperature |
|
On the enclosure |
|
|
< 0.2 %/10 K of full-scale value |
|
< 0.2 %/10 K of full-scale value |
On the process connection (remote seals) |
Zero error (depends on design) |
|
|
|
4.8 mbar/10 K (0.070 psi/10 K) |
|
2.3 mbar/10 K (0.033 psi/10 K) |
|
1.6 mbar/10 K (0.023 psi/10 K) |
|
0.6 mbar/10 K (0.009 psi/10 K) |
|
|
|
9.5 mbar/10 K (0.138 psi/10 K) |
|
4.1 mbar/10 K (0.060 psi/10 K) |
|
3.9 mbar/10 K (0.057 psi/10 K) |
|
3.9 mbar/10 K (0.057 psi/10 K) |
The zero error specified for the process connection should be considered as a guideline for a standard design. We will produce a detailed system calculation on request. Systems with reduced remote seal errors are available on request. |
Rated conditions |
|
Installation conditions |
|
|
Any, vertical as standard |
Ambient conditions |
|
|
-10 ... +70 °C (14 ... 158 °F) |
|
-10 ... +90 °C (14 ... 194 °F) |
|
Max. 200 °C (392 °F), depending on design |
- Degree of protection (to EN 60529)
|
IP65, optional IP67 |
- Electromagnetic compatibility
|
|
|
To EN 50081 Part 1, issue 1993 (residential and industrial areas). The unit has no own emissions. |
|
EN 50082 Part 2, issue March 1995 (industrial areas) |
Construction |
|
Weight (without remote seal) |
|
|
˜ 460 g (˜ 1.01 lb) |
|
˜ 200 g (˜ 0.44 lb) |
Enclosure |
|
|
- Field housing IP65 or IP67, with screwed gland
- Angled plug DIN 43650, IP65
- Cable connection, IP67
- Round plug connector M12, IP65
|
|
Stainless steel, mat. No. 1.4404/316L/1.4305 |
Material of union nut |
Polyamide (with electrical connection using plug or cable)
Electronics unit potted with silicone
Internal ventilation for measuring ranges < 16 bar (< 232 psi), through housing thread or connecting cable depending on design |
Process connection |
|
|
See ordering data |
|
Stainless steel, mat. No. 1.4404/316L |
Power supply |
|
Terminal voltage on transmitter |
10 ... 30 V DC |
Rated voltage |
24 V DC |
Certificates and approvals |
|
Classification according to pressure equipment directive (DRGL 97/23/EC) |
For gases of fluid group 1 and liquids of fluid group 1; complies with the requirements of Article 3, paragraph 1 (appendix 1); assigned to category III, conformity evaluation module H by the TÜV Nord |
Explosion protection |
|
|
TÜV 03 ATEX 2099 X |
|
Ex II 2G EEx ib IIC T6 |