   PRODUCT: 
MAG 1100



Code: 7ME6110/7ME6120
Product name: MAG 1100

The SITRANS F M MAG 1100 is an electromagnetic flow sensor in a compact wafer design designed for flow applications in the process industry.

 

Version

MAG 1100

MAG 1100 HT (High temperature)

Measuring principle

Electromagnetic induction

Electromagnetic induction

Excitation frequency

  • DN 2 ... 65 (1/12“ … 2½”): 12.5 Hz
  • DN 80, 100 (3”, 4”): 6.25 Hz
  • DN 15 ... 50 (½“ … 2”): 12.5 Hz
  • DN 80, 100 (3”, 4”): 6.25 Hz

Process connection

   

Nominal size

   
  • MAG 1100 (Ceramic)

DN 2 … DN 100 (1/12" … 4")

DN 15 … DN 100 (½” … 4")

  • MAG 1100 (PFA)

DN 10 … DN 100 (3/8" … 4")

 

Mating flanges

EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 or equivalent

Option:
DN 2 ... 10 (1/12” ... 3/8”): G½” / NPT ½” pipe connection adapters

EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 or equivalent

Rated operating conditions

   

Ambient conditions

   

Ambient temperature1)

   
  • Sensor

-40 … +100 °C (-40 … +212 °F)

-40 … +100 °C (-40 … +212°F)

  • Sensor ATEX

-20 … +60 °C (-4 … +140 °F)

 
  • Compact transmitter MAG 5000/6000

-20 … +50 °C (-4 … +122°F)

 
  • Compact transmitter MAG 6000 I

-20 … +60 °C (-4 … +140 °F)

 
  • Compact transmitter MAG 6000 I Ex d

-10 … +60 °C (+14 … +140 °F)

 

Temperature of medium

   
  • MAG 1100 (Ceramic)

-20 … +150 °C (-4 … +302°F)

-20 … +200 °C (-4 … +392°F)

  • MAG 1100 ATEX (Ceramic)

-20 … +150 °C (-4 … +302°F)

-20 … +180C (-4 … +356°F)

  • MAG 1100 (PFA)

-30 … +130 °C (-20 … +266F)
Suitable for steam sterilization at 150 °C (302°F)

 

Temperature shock

   
  • MAG 1100 (Ceramic)
   
    • Duration ≤ 1 min, followed by 10 min rest
  • DN 2, 3 (1/12”, 1/8”) No limitations
  • DN 6, 10, 15, 25:
    Max. DT ≤ 80 °C/min (¼”, 3/8”, ½”, 1”: Max. DT ≤ 80 K/min)
  • DN 40, 50, 65:
    Max. DT ≤ 70 °C/min (1½”, 2”, 2½”: Max. DT ≤ 70 K/min)
  • DN 80, 100: Max. DT ≤ 60 °C/min (3”, 4”: Max. DT ≤ 60 K/min)
  • DN 15, 25: Max. DT ≤ 80 °C/min (½”, 1”: Max. DT ≤ 80 K/min)
  • DN 40, 50: Max. DT ≤ 70 °C/min (1½”, 2”: Max. DT ≤ 70 K/min)
  • DN 80, 100: Max. DT ≤ 60 °C/min (3”, 4”: Max. DT ≤ 60 K/min)
  • MAG 1100 (PFA)

Max. ±100 °C (210 °F) momentarily

 

Operating pressure

   
  • MAG 1100 (Ceramic)
  • DN 2 ... 65: 40 bar
    (1/12” … 2½”: 580 psi)
  • DN 80: 37.5 bar (3”: 540 psi)
  • DN 100: 30 bar (4”: 435 psi)

Vacuum: 1 x 10-6abs1.5 x 10-5 psiabs bar

  • DN 15 ... 50: 40 bar
    (½” … 2”: 580 psi)
  • DN 80: 37.5 bar (3”: 540 psi)
  • DN 100: 30 bar (4”: 435 psi)

Vacuum: 1 x 10-6abs1.5 x 10-5 psiabs) bar

  • MAG 1100 (PFA)

20 bar (290 psi)

Vacuum: 0.02 barabs (0.3 psiabs)

DN 80 ... DN 100: CO2 pressure max. 7 bar (101.5 psi)

 

Mechanical load

  • 18 … 1 000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
  • Sensor: 3.17 grms
  • Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms
  • Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 grms
  • For compact installation with the MAG 6000 I, transmitter to be supported to avoid tension on sensor part.
  • 18 … 1 000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
  • Sensor: 3.17 grms

Enclosure rating

   
  • Standard

IP67 to EN 60529 (NEMA 4X/6), 1 mH2O for 30 min

IP67 to EN 60529 (NEMA 4X/6), 1 mH2O for 30 min

  • Option on sensor (no ATEX)

IP68 to EN 60529 (NEMA 6P), 10 mH2O cont.

IP68 to EN 60529 (NEMA 6P), 10 mH2O cont.

EMC

89/336 EEC

89/336 EEC

Design

   

Weight

See Dimensional drawings

See Dimensional drawings

Material

   
  • Enclosure
   
    • MAG 1100

Stainless steel AISI 316L (1.4404)

Stainless steel AISI 316L (1.4404)

  • Terminal box
   
  • Standard

Fibre glass reinforced polyamide (no ATEX)

Stainless steel AISI 316 (1.4436)

  • Option

Stainless steel AISI 316 (1.4436)

 
  • Fixing studs

Stainless steel AISI 304 (1.4301),

Number and size to EN 1092-1:2001

Stainless steel AISI 304 (1.4301),

Number and size to EN 1092-1:2001

  • Gaskets
   
  • Standard

EPDM (max. 150 °C, PN 40 (max. 300 °F, 600 psi)

Graphite (max. 200 °C, PN 40 (max. 390 °F, 600 psi)

  • Option
  • Graphite (max. 200 °C, PN 40 (max. 390 °F, 600 psi)
  • PTFE (max. 130 °C, PN 25 (max. 270 °F, 300 psi)
 
  • Pipe connection adapters:
    DN 2, 3, 6 and 10 (1/12“, 1/8“, ¼” and 3/8”)
  • Stainless steel, AISI 316
  • Hastelloy
  • PVDF
 

Liner

   
  • MAG 1100 (Ceramic)
  • DN 2, 3 (1/12“, 1/8“): Zirconium oxide (ZrO2)
  • DN 6 ... 100 (¼" ... 4"): Aluminium oxide Al2O3

DN 15 ... 100 (½“, 4“): Aluminium oxide Al2O3

  • MAG 1100 (PFA)

Reinforced PFA (no ATEX)

 

Electrodes

   
  • MAG 1100 (Ceramic)
  • DN 10 ... 100 (3/8" ... 4") : Platinum with gold / Titanium brazing alloy
  • DN 2 ... 6 (1/12" ... ¼"): Platinium

Platinum with gold / Titanium brazing alloy

  • MAG 1100 (PFA)
  • DN 10 ... 15 (3/8" ... ½") : Hastelloy C276
  • DN 25 ... 100 (1" ... 4") : Hastelloy C22
 

Cable entries

  • Remote installation 2 x M20 or 2 x ½” NPT
  • Compact installation
    • MAG 5000/MAG 6000: 4 x M20 or 4x½”NPT
    • MAG 6000I: 2 x M25 (for supply/output)
    • MAG 6000I Ex d: 2 x M20 (for supply/output)

Remote installation 2 x M20 or 2 x ½“ NPT

Certificates and approvals

   

Conforms to

PED – 97/23 EC and CRN (PFA)

PED – 97/23 EC and CRN (PFA)

Ex approvals

   

MAG 1100 (Ceramic)

   
  • ATEX sensor or Compact with MAG 6000 I Ex

ATEX 2G D sensor Ex d e ia IIB T3 - T6

ATEX 2G D sensor Ex d e ia IIB T3 - T6

  • Sensor with/without MAG 5000/6000 /6000 I

CSA/FM Class 1 div 2

CSA/FM Class 1 div 2

MAG 1100 (PFA)

   
  • Sensor with/without MAG 5000/6000/6000 I

CSA/FM Class 1 div 2

 

1) Conditions are also dependent on liner characteristics

For technical specification for transmitter - please see transmitter pages.

 

Share |
Video clips
Hot News
Certificates
Online Support
Sales Support
0901 185 205
Support via Skype     Support via Yahoo Messanger    
Technical Support
0938 77 40 99
Support via Skype     Support via Yahoo Messanger    
 
An Thinh Automation Ltd.,
26/50 Nguyen Minh Hoang street, Tan Binh District, HCM City, Viet Nam
Tel:(84) 08 3948 1715         Fax: (84) 08 3811 1332