|
Mã sản phẩm:
CCU Chemical Changeover Controller
Tên sản phẩm:
CCU Chemical Changeover Controller
|
USF Wallace & Tiernan continue to be the leader in the disinfection of potable, waste,
industrial process and leisure water applications.
|
80 Year of Experience USF Wallace & Tiernan continue to be the leader in the disinfection of potable, waste, industrial process and leisure water applications. With over 80 years of experience, the design and manufacture of chemical feed and disinfection products, using the collective expertise of the USF Wallace & Tiernan centres around the world, continues to produce safe and reliable methods of controlling the addition of chemicals to water sources. Designed to meet the global needs for the automatic changeover between two chemical supplies, the Wallace & Tiernan CCU (Chemical Changeover Unit) is no exception. Efficcient Chemical Controll Automatic changeover of chemical supplies, from a duty to a standby supply, is a necessity in many installations which are not under constant supervision and is strongly recommended for all applications where temporary interruption of chemical supply might lead to unwanted complications. The CCU will provide this automatic changeover to ensure continuous chemical supply. The supply of chemical is controlled by a 3-port motorised valve, or by a pair of 2-port motorised valves. A pressure switch, or gauge is used to initiate changeover when the pressure falls to a preset level. By utilising different valve arrangements, the CCU provides automatic changeover for a variety of chemicals in both pressure and vacuum systems. The CCU will provide changeover in low or high pressure installations and will handle both gas and liquid valve arrangements as illustrated in the following typical layouts. Main Features • Duty / standby valve changeover ensuring continuous chemical supply • Pressure or vacuum operation • Suitable for use with a wide variety of chemicals • Controls single 3-port valve or two 2-port valves • LED’s provide visual indication of Valve Open / Exhausted for each supply • Full monitoring of valve positions - an alarm is generated if a valve fails to open or close • Changeover initiated by 1 or 2 pressure / switches - switch contacts may be normally open or normally closed • Shutdown input may be used to disconnect both supplies in an emergency (only available when 1 pressure / vacuum switch is used) • Volt-free Running contacts indicate which supply is being used • Volt-free Alarm contacts indicate when a chemical supply is exhausted • Manual changeover facility • Inhibit timer prevents pressure switch, or gauge, from initiating change before a supply is fully on line • Reset option returns CCU to known state following power up
|
|
|