SITRANS TR300



Mã sản phẩm: 7NG3033-0JN00
Tên sản phẩm: SITRANS TR300

"HART" to beat - the universal SITRANS TR300 transmitter

 

Input

 

Resistance thermometer

 

Measured variable

Temperature

Sensor type

 
  • to IEC 60751

Pt25 to Pt1000

  • to JIS C 1604; a=0.00392 K-1

Pt25 to Pt1000

  • to IEC 60751

Ni25 to Ni1000

  • Special type

Over special characteristic (max. 30 points)

Sensor factor

0.25 ... 10 (adaptation of the basic type, e.g. Pt100 to version Pt25 ... Pt1000)

Units

°C or °F

Connection

 
  • Standard connection

1 resistance thermometer (RTD) in 2-wire, 3-wire or 4-wire system

  • Generation of average value

2 identical resistance thermometers in 2-wire system for generation of average temperature

  • Generation of difference

2 identical resistance thermometers (RTD) in 2-wire system (RTD 1 – RTD 2 or RTD 2 – RTD 1)

Interface

 
  • Two-wire system

Parameterizable line resistance ≤ 100 Ω (loop resistance)

  • Three-wire system

No balancing required

  • Four-wire system

No balancing required

Sensor current

≤ 0.45 mA

Response time T63

≤ 250 ms for 1 sensor with open-circuit monitoring

Open-circuit monitoring

Always active (Cannot switched off)

Short-circuit monitoring

Can be switched off (value is adjustable)

Range

Parameterizable (see table "Digital measuring errors")

Min. measured span

10 °C (18 °F)

Characteristic

Temperature-linear or special characteristic

Resistance-based sensors

 

Measured variable

Actual resistance

Sensor type

Resistance-based, potentiometers

Units

Ω

Connection

 
  • Normal connection

1 resistance-based sensor (R) in 2-wire, 3-wire or 4-wire system

  • Generation of average value

2 resistance-based sensors in 2-wire system for generation of average value

  • Generation of difference

2 resistance thermometers in 2-wire system
(R1 – R2 or R2 – R1)

Interface

 
  • Two-wire system

Parameterizable line resistance ≤ 100 Ω (loop resistance)

  • Three-wire system

No balancing required

  • Four-wire system

No balancing required

Sensor current

≤ 0.45 mA

Response time T63

≤ 250 ms for 1 sensor with open-circuit monitoring

Open-circuit monitoring

Always active (cannot switched off)

Short-circuit monitoring

Can be switched off (value is adjustable)

Range

Parameterizable, max. 0 ... 2200 Ω (see Table "Digital measuring errors")

Min. measured span

5 Ω ... 25 Ω (see Table "Digital measuring errors")

Characteristic

Resistance-linear or special characteristic

Thermocouple elements

 

Measured variable

Temperature

Sensor type (thermocouples)

 
  • Type B

Pt30Rh-Pt6Rh to DIN IEC 584

  • Type C

W5 %-Re to ASTM 988

  • Type D

W3 %-Re to ASTM 988

  • Type E

NiCr-CuNi to DIN IEC 584

  • Type J

Fe-CuNi to DIN IEC 584

  • Type K

NiCr-Ni to DIN IEC 584

  • Type L

Fe-CuNi to DIN 43710

  • Type N

NiCrSi-NiSi to DIN IEC 584

  • Type R

Pt13Rh-Pt to DIN IEC 584

  • Type S

Pt10Rh-Pt to DIN IEC 584

  • Type T

Cu-CuNi to DIN IEC 584

  • Type U

Cu-CuNi to DIN 43710

Units

°C or °F

Connection

 
  • Standard connection

1 thermocouple (TC)

  • Generation of average value

2 thermocouples (TC)

  • Generation of difference

2 thermocouples (TC) TC1 – TC2 or TC2 – TC1

Response time T63

≤ 250 ms for 1 sensor with open-circuit monitoring

Open-circuit monitoring

Can be switched off

Cold junction compensation

 
  • Internal

With integrated Pt100 resistance thermometer

  • External

With external Pt100 IEC 60571 (2-wire or 3-wire connection)

  • External fixed

Cold junction temperature can be set as fixed value

Range

Parameterizable (see table "Digital measuring errors")

Min. measured span

Min. 50 ... 199 °C (90 ... 180 °F) (see table "Digital measuring errors")

Characteristic

Temperature-linear or special characteristic

mV Sensor

 

Measured variable

DC voltage

Sensor type

DC voltage source (DC voltage source possible over an externally connected resistor)

Units

mV

Response time T63

≤ 250 ms for 1 sensor with open-circuit monitoring

Open-circuit monitoring

Can be switched off

Short-circuit monitoring

Can be switched off (value is adjustable)

Range

Parameterizable max. -100 … 1100 mV

Min. measured span

2 mV or 20 mV

Overload capacity of the input

-1.5 ... +3.5 V DC

Input resistance

≥ 1 MΩ

Characteristic

Voltage-linear or special characteristic

Output

 

Output signal

4 ... 20 mA, 2-wire
Communication acc. to HART Rev. 5.9

Power supply

11 ... 35 V DC (to 30 V with EEx)

Max. load

(Uaux – 11 V)/0.023 A

Overrange

3.6 ... 23 mA, continuously adjustable (default range: 3.84 ... 20.5 mA)

Error signal (e.g. in the event of sensor breakage)

3.6 ... 23 mA, continuously adjustable (default value: 22.8 mA)

Sample cycle

0.25 s nominal

Damping

Software filter 1st order 0 ... 30 s (parameterizable)

Protection

Against reversed polarity

Electrically isolated

Input against output (1 kVeff)

Measuring accuracy

 

Digital measuring errors

See Table "Digital measuring errors"

Reference conditions

 
  • Power supply

24 V ± 1 %

  • Load

500 Ω

  • Storage temperature

23 °C

  • Warming-up time

> 5 min

Error in the analog ouput (digital/analog converter)

< 0.1 % of span

Error due to internal cold junction

< 0.55 °C (0.9 °F)

Temperature effect

< 0.1 % der max. span/10°C (18 °F)

Power supply effect

< 0.005 % of span/V

Effect of load impedance

< 0.012 % of span/100 Ω

Long-term drift

 
  • in the first month

< 0.02 % of max. span

  • after one year

< 0.03 % of max. span

  • after 5 years

< 0.04 % of max. span

Rated conditions

 

Ambient temperature

 

Storage temperature

-40 ... +85 °C (-40 ... 185 °F)

Functional temperature

-40 ... +85 °C (-40 ... 185 °F)

Relative humidity

< 98 %, with condensation

Electromagnetic compatibility

acc. to DIN EN 61326 and NAMUR NE21

Construction

 

Material

Plastic, electronic module potted

Approx. weight

122 g (0.27 lb)

Dimensions

See "Dimension drawings"

Cross-section of cables

Max. 2.5 mm² (AWG 13)

Degree of protection to EN 60529

 
  • Enclosure

IP40

  • Terminals

IP00

Certificate and approvals

 

Explosion protection ATEX

 

EC type test certificate

PTB 07 ATEX 2032X

  • "Intrinsic safety" type of protection

II 2(1) G Ex ia/ib IIC T6/T4

II 3(1) G Ex ia/ic IIC T6/T4

II 2(1) D Ex iaD/ibD 20/21 T115 °C

  • Type of protection, "equipment has limited energy"

II 3 G Ex nL IIC T6/T4

  • Type of protection, "equipment is non-arcing"

II 3 G Ex nA IIC T6/T4

Software requirements for SIPROM T

 

PC operating system:

Windows ME, 2000 and XP; also Windows 95, 98 and 98 SE, but only in connection with RS 232 modem.


Factory setting:

  • Pt100 (IEC 751) with three-wire circuit
  • Measuring range: 0 ... 100 °C (32 ... 212 °F)
  • Fault current: 22.8 mA
  • Sensor offset: 0 °C (0 °F)
  • Damping 0.0 s

Digital measuring errors

Resistance thermometer

input

Range

Min. measured span

Digital accuracy

 

°C (°F)

°C

(°F)

°C

(°F)

to IEC 60751

         

Pt25

-200 ... +850 (-328 ... +1562)

10

(18)

0.2

(0.36)

Pt50

-200 ... +850 (-328 ... +1562)

10

(18)

0.15

(0.27)

Pt100 ... Pt200

-200 ... +850 (-328 ... +1562)

10

(18)

0.1

(0.18)

Pt500

-200 ... +850 (-328 ... +1562)

10

(18)

0.15

(0.27)

Pt1000

-200 ... +350 (-328 ... +662)

10

(18)

0.15

(0.27)

to JIS C1604-81

         

Pt25

-200 ... +649 (-328 ... +1200)

10

(18)

0.2

(0.36)

Pt50

-200 ... +649 (-328 ... +1200)

10

(18)

0.15

(0.27)

Pt100 ... Pt200

-200 ... +649 (-328 ... +1200)

10

(18)

0.1

(0.18)

Pt500

-200 ... +649 (-328 ... +1200)

10

(18)

0.15

(0.27)

Pt1000

-200 ... +350 (-328 ... +662)

10

(18)

0.15

(0.27)

Ni 25 to Ni1000

-60 ... +250 (-76 ... +482)

10

(18)

0.1

(0.18)


Resistance-based sensors

Input

Range

Min. measured span

Digital accuracy

 

Ω

Ω

Ω

Resistance

0 ... 390

5

0.05

Resistance

0 ... 2200

25

0.25


Thermocouples

Input

Measuring range

Min. measured span

Digital accuracy

 

°C

(°F)

°C

(°F)

°C

(°F)

Type B

0 ... 1820

(32 ... 3308)

100

(180)

21)

(3.60)1)

Type C (W5)

0 ... 2300

(32 ... 4172)

100

(180)

2

(3.60)

Type D (W3)

0 ... 2300

(32 ... 4172)

100

(180)

12)

(1.80)2)

Type E

-200 ... +1000

(-328 ... +1832)

50

(90)

1

(1.80)

Type J

-210 ... +1200

(-346 ... +2192)

50

(90)

1

(1.80)

Type K

-230 ... +1370

(-382 ... +2498)

50

(90)

1

(1.80)

Type L

-200 ... +900

(-328 ... +1652)

50

(90)

1

(1.80)

Type N

-200 ... +1300

(-328 ... +2372)

50

(90)

1

(1.80)

Type R

-50 ... +1760

(-58 ... +3200)

100

(180)

2

(3.60)

Type S

-50 ... +1760

(-58 ... +3200)

100

(180)

2

(3.60)

Type T

-200 ... +400

(-328 ... +752)

40

(72)

1

(1.80)

Type U

-200 ... +600

(-328 ... +1112)

50

(90)

2

(3.60)


1) The digital accuracy in the range 0 to 300 °C (32 to 572 °F) is 3 °C (5.4 °F).

2) The digital accuracy in the range 1750 to 2300 °C (3182 to 4172 °F) is 2 °C (3.6 °F).

mV Sensor

input

Range

Min. measured span

Digital accuracy

 

mV

mV

μV

mV Sensor

-10 ... +70

2

40

mV Sensor

-100 ... +1100

20

400


The digital accuracy is the accuracy after the analog/digital conversion including linearization and calculation of the measured value.

An additional error is generated in the output current 4 to 20 mA as a result of the digital/analog conversion of 0.1 % of the set span (digital-analog error).

The total error under reference conditions at the analog output is the sum from the digital error and the digital-analog error (poss. with the addition of cold junction errors in the case of thermocouple measurements).

 

Share |
Video clips
Tin tức mới
Các giấy chứng nhận
Hỗ trợ trực tuyến
Sales Support
0901 185 205
    Support via Yahoo Messanger    
Technical Support
0938 77 40 99
    Support via Yahoo Messanger    
 
Công ty TNHH An Thịnh Tự Động
Trụ sở chính: 186/15 Phan Văn Trị, P.12, Q.Bình Thạnh, TP.HCM
VPGD: 26/1 Nguyễn Bỉnh Khiêm, P. Đa Kao, Q.1, TP HCM
Tel:(84) 28 3910 3379         Fax: (84) 28 3910 3378         Email: info@anthinh.com.vn