OCM III



Mã sản phẩm: 7ML1002
Tên sản phẩm: OCM III

The OCM III is a high accuracy ultrasonic flow monitor for open channels.

 

Mode of Operation

 

Measuring range1)

 0.3 to 1.2 m (1 to 4 ft) or 0.6 to 3 m (2 to 10 ft)

Output

 

Transducer

Echomax® XRS-5, 44 kHz

Relays

3 alarm/control relays, 1 SPDT Form C contact per relay, rated 5 A at 250 V AC non-inductive or 30 V DC

mA output

0/4 to 20 mA, isolated

  • Max. load

1 KΩ max. load

  • Resolution

5 uA

  • Isolation

300 V AC continuous

  • DC output

+24 V DC, 20 mA average to 200 mA at 1/10 duty cycle max. 0 to 20

Accuracy

 

Error in measurement

±1 mm/m, calculated error less than 0.02%

Resolution

0.2 mm (0.007")

Rated operating conditions

 

Installation conditions

 

Location

Indoor/outdoor

Installation category

II

Pollution degree

4

Ambient conditions

 

Ambient temperature (enclosure)

-20 to +50 °C (-5 to +122 °F)

Design

 

Weight

2.3 kg (5.1 lbs)

Material (enclosure)

Polycarbonate

Degree of protection (enclosure)

IP65/Type 4X/NEMA 4X

Cable

 

Transducer and mA output signal

  • Transducer: co-axial to be RG62-A/U low capacity
  • mA output signal to be 2 copper conductors, twisted, with foil shield/drain wire, 300 V 0.5 to 0.75 mm² (22 to 18 AWG)
  • Relay/power to be copper conductors per local requirements to meet 250 V 5 A contact rating

Max. separation between transducer and transceiver

183 m (600 ft)

Displays and controls

LCD 5 x 7 dot matrix display with 2 lines of 40 characters each

Programming

Via removable programmer and communication link

Memory

3 V battery (NEDA 5003LC or equivalent), operating life 1 year, SuperCap capacitor for back-up during battery replacement

Power supply

 

AC version

100/115/200/230 V AC ± 15%, 50/60 Hz, 20 VA max.

DC version

9 to 30 V DC, 8 W max.

Certificates and approvals

CE, FM, CSANRTL/C, MCERTS,
C-TICK2)

Communication

RS-232 or ± 20 mA bipolar current loop, 300, 600, 1200, 2400, 4800, 9600, 19200 baud

Options

 

Temperature sensor

TS-2

Remote monitoring

Flow Reporter, a Windows®-based configuration software and data extractor

Velocity sensor

Consult with factory


1) Program range is defined as the empty distance to the face of the transducer plus any range extension
2) EMC performance available upon request
Windows® is a registered trademark of Microsoft Corporation

 

Share |
Video clips
Tin tức mới
Các giấy chứng nhận
Hỗ trợ trực tuyến
Sales Support
0901 185 205
    Support via Yahoo Messanger    
Technical Support
0938 77 40 99
    Support via Yahoo Messanger    
 
Công ty TNHH An Thịnh Tự Động
Trụ sở chính: 186/15 Phan Văn Trị, P.12, Q.Bình Thạnh, TP.HCM
VPGD: 26/1 Nguyễn Bỉnh Khiêm, P. Đa Kao, Q.1, TP HCM
Tel:(84) 28 3910 3379         Fax: (84) 28 3910 3378         Email: info@anthinh.com.vn