Nominal size |
DN 15 ... DN 2000 (½” ... 78“) |
DN 15…DN 300 (½“ ... 12“) |
DN 15…DN 300 (½“ ... 12“) |
Measuring principle |
electromagnetic induction |
electromagnetic induction |
electromagnetic induction |
Excitation frequency |
- DN 15 ... 65 (½“ … 2½”): 12.5 Hz
- DN 80 ... 150 (3” ... 6”): 6.25 Hz
- DN 200 ... 1200 (8” ... 48”): 3.125 Hz
- DN 1400 ... 2000 (54” ... 78”): 1.5625 Hz
|
- DN 15 ... 65 (½“ … 2½”): 12.5 Hz
- DN 80 ... 150 (3” ... 6”): 6.25 Hz
- DN 200 ... 300 (8” ... 12”): 3.125 Hz
|
- DN 15 ... 65 (½“ … 2½”): 12.5 Hz
- DN 80 ... 150 (3” ... 6”): 6.25 Hz
- DN 200 ... 300 (8” ... 12”): 3.125 Hz
|
Process connection |
Flanges |
EN 1092-1, raised face (EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions)
- DN 65 ... 2000 (2½“ … 48”): PN 6 (87 psi)
- DN 200 ... 2000 (8“ … 48“):PN 10 (145 psi)
- DN 65 ... 2000 (2½“ … 78“): PN 16 (232 psi)
- DN 200 ... 600 (8“ … 24”): PN 25 (362 psi)
- DN 15 ... 600 (½“ … 24”): PN 40 (580 psi)
- DN 50 ... 300 (2“ … 12“): PN 63 (913 psi)
- DN 25 ... 300 (1“ … 12“): PN 100 (1450 psi)
ANSI B16.5 (~BS 1560), raised face
- ½” ... 24”: Class 150 (20 bar (290 psi))
- ½” ... 24”: Class 300 (50 bar (725 psi))
AWWA C-207, flat face 28” ... 78”: Class D (10 bar)
AS 2129, raised face ½” ... 48”: Table E
AS 4087, raised face:
- PN 16 (DN 50 ... 1200, 16 bar (232 psi))
- PN 21 (DN 50 ... 600, 21 bar (304 psi))
- PN 35 (DN 50 ... 600, 35 bar (508 psi))
Other flanges and pressure ratings on request |
EN 1092-1, raised face (EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions)
- DN 15 ... 300 (½“ … 12”): PN 40 (580 psi)
- DN 65 ... 300 (2½“ … 12”):PN 16 (232 psi)
- DN 200 ... 300 (8“ … 12“):PN 10 (145 psi)
- DN 200 ... 300 (8“ … 12”): PN 25 (362 psi)
ANSI B16.5 (~BS 1560), raised face:
- ½” ... 12”: Class 150 (20 bar (290 psi))
- ½” ... 12”: Class 300 (50 bar (725 psi))
AS 2129, raised face ½” ... 12”: Table E
Other flanges and pressure ratings on request |
EN 1092-1, raised face (EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions)
- DN 15 ... 50 (½“ … 2”): PN 40 (580 psi)
- DN 65 ... 300 (2½“ … 12”):PN 16 (232 psi)
- DN 200 ... 300 (8“ … 12“):PN 10 (145 psi)
ANSI B16.5 (~BS 1560), raised face
- ½” ... 12”: Class 150 (20 bar (290 psi))
|
Rated operation conditions |
Ambient temperature (conditions also dependent on liner characteristiques) |
|
|
|
Sensor |
-40 … +100 ºC (-40 … +212 °F) |
-40 … +100 ºC (-40 … +212 °F) |
-40 … +100 ºC (-40 … +212 °F) |
|
-20 … +60 ºC (-4 … +140 °F) |
For up to 150 °C (302 °F) temperature of medium: -20 … +60 ºC (-4 … +140 °F)
For 150 … 180 °C (302 … 356 °F) temperature of medium: -20 … +50 ºC (-4 … +122 °F) |
-20 … +60 ºC (-4 … +140 °F) |
- With compact transmitter MAG 5000/6000
|
-20 … +50 ºC (-4 … +122 °F) |
-20 … +50 ºC (-4 … +122 °F) |
-20 … +50 ºC (-4 … +122 °F) |
- With compact transmitter MAG 6000 I
|
-20 … +60 ºC (-4 … +140 °F) |
-20 … +60 ºC (-4 … +140 °F) |
-20 … +60 ºC (-4 … +140 °F) |
- With compact transmitter MAG 6000 I Ex d
|
-10 … +60 ºC (14 … 140 °F) |
-10 … +60 ºC (14 … 140 °F) |
-10 … +60 ºC (14 … 140 °F) |
Operating pressure |
Operating pressure [abs. bar] (maximum operating pressure decreases with increasing operating temperature and with stainless steel flanges) |
- Neoprene 0.01 ... 100 bar
- (0.15 ... 1450 psi)
- EPDM 0.01 ... 40 bar (0.15 ... 580 psi)
- Linatex® 0.01 ... 40 bar (0.15 ... 580 psi)
- Ebonite 0.01 ... 100 bar
(0.15 ... 1450 psi)
- PTFE (DN ≤ 300, 0.3 … 50 bar/
≤ 12“, 4 … 725 psi) (350 ≤ DN ≤ 600/14“≤ DN ≤ 24“) 0.3 ... 40 bar (4 ... 580 psi)
- PFA
- DN 25 ... 100 (1“ … 4”): 0.01 ... 50 bar (0.15 ... 725 psi)
|
- PTFE Teflon
- DN 15 ... 300 (½“ … 12”) (130/180 °C (266 °F/356ºF)): 0.3/0.6 ... 50 bar
(4/8 ... 725 psi) (180 ºC (356 ºF) PTFE has factory mounted grounding SS rings type E & SS terminal box)
- PFA
- DN 25 ... 100 (1“ … 4”): 0.01 ... 50 bar (0.15 ... 725 psi)
|
- PTFE Teflon
- DN 15 ... 300 (½“ … 12”): 0.3 ... 50 bar (4 ... 725 psi)
- PFA
- DN 15 ... 100 (1“ … 4”): 0.01 ... 50 bar (0.15 ... 725 psi)
|
Enclosure rating |
IP67/NEMA 4X/6 to EN 60529, 1 mH2O for 30 min
Option: IP68/NEMA 6P to EN 60529,10 mH2O cont. (no ATEX) |
IP67/NEMA 4X/6 to EN 60529, 1 mH2O for 30 min
Option: IP68/NEMA 6P to EN 60529,10 mH2O cont. (no ATEX) |
IP67/NEMA 4X/6 to EN 60529, 1 mH2O for 30 min
Option: IP68/NEMA 6P to EN 60529,10 mH2O cont. (no ATEX) |
Pressure drop at 3 m/s |
As straigth pipe |
As straigth pipe |
As straigth pipe |
Test pressure |
1.5 x PN (where applicable) |
1.5 x PN (where applicable) |
1.5 x PN (where applicable) |
Mechanical load |
- 18 ... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
- Sensor: 3.17 grms
- Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms
- Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 grms
|
- 18 ... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
- Sensor: 3.17 grms
- Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms
- Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 grms
|
- 18 ... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
- Sensor: 3.17 grms
- Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms
- Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 grms
|
Temperature of medium |
- Neoprene 0 … +70 °C (32 … 158 °F)
- EPDM -10 … +70 °C (+14 … +158 °F)
- Linatex® (rubber) -40 … +70 °C
(-40 … +158 °F) (for temperatures below -20 °C (-4 °F) AISI 304 or 316 flanges must be used)
- Ebonite 0 … 95 °C (32 … 203 °F)
- PTFE -20 … +100 °C (-4 … +212 °F)
- PFA -20 … +100 °C (-4 … +212°F)
|
- PTFE -20 … +130 °C (-4 … +266 °F)
- PTFE -20 … +180 °C (-4 ... +356 °F) Factory mounted grounding rings type E and SS terminal box. Can only be used with remote transmitter.
- PFA -20 … +150 °C (-4 … +300 °F)
|
PTFE -20 … +130 °C (-4 … +266 °F)
PFA -20 … +150 °C (-4 … +300 ºF) |
EMC |
89/336 ECC |
89/336 ECC |
89/336 ECC |
Design |
Weight |
See dimensional drawings |
Flange and housing material |
Carbon steel ASTM A 105, with corrosion resistant two component epoxy coating (min. 150 mm) (PN 16 Non PED in size DN 700 ... 2000: Mild Steel)
or
AISI 304 (1.4301) flanges and carbon steel housing, with corrosion resistant two component epoxy coating (min. 150 mm)
or
AISI 316 L (1.4404) flanges and housing, polished |
Carbon steel ASTM A 105, with corrosion resistant two component epoxy coating (min. 150 mm)
or
AISI 304 (1.4301) flanges and carbon steel housing, with corrosion resistant two component epoxy coating (min. 150 mm)
or
AISI 316 L (1.4404) flanges and housing, polished |
Carbon steel ASTM A 105, with corrosion resistant two component epoxy coating (min. 150 mm) |
Measuring pipe material |
AISI 304 (1.4301) (AISI 316L (1.4404) flanges and housing, polished has measuring pipe of AISI 316L (1.4435)) |
AISI 304 (1.4301) (AISI 316L (1.4404) flanges and housing, polished has measuring pipe of AISI 316L (1.4435)) |
AISI 304 (1.4301) |
Electrode material |
- AISI 316 Ti (1.4571)
- Hastelloy C276 (PFA: Hastelloy C22)
- Platinum/Iridium,
- Titanium
- Tantalum
|
- AISI 316 Ti (1.4571)
- Hastelloy C276 (PFA: Hastelloy C22)
- Platinum/Iridium,
- Titanium
- Tantalum
|
Hastelloy C276 (PFA: Hastelloy C22) |
Grounding Electrode material |
Material as measuring electrodes: Exceptions - see ordering data |
No grounding electrodes |
No grounding electrodes |
Terminal box (remote version only) |
- Standard Fibre glass-reinforced polyamide
- Option Stainless steel AISI 316 (1.4436)
- Ex ATEX (remote version only) Stainless steel AISI 316 (1.4436)
|
- Stainless steel AISI 316 (1.4436)
- Ex ATEX (remote version only) Stainless steel AISI 316 (1.4436)
|
- Standard Fibre glass-reinforced polyamide
- Option Stainless steel AISI 316 (1.4436)
- Ex ATEX (remote version only) Stainless steel AISI 316 (1.4436)
|
Cable entries |
- Remote installation 2xM20 or 2x½ NPT
- Compact installation
- MAG 5000/MAG 6000: 4xM20 or 4x½”NPT
- MAG 6000 I: 2xM25(for supply/output)
- MAG 6000I Ex. d: 2xM20 (for supply/output)
|
- Remote installation 2xM20 or 2x½ NPT
|
- Remote installation 2xM20 or 2x½ NPT
- Compact installation
- MAG 5000/MAG 6000: 4xM20 or 4x½”NPT
- MAG 6000 I: 2xM25(for supply/output)
MAG 6000I Ex. d: 2xM20 (for supply/output) |
Certificates and approvals |
Conforms to |
PED – 97/23 EC, CRN |
PED – 97/23 EC, CRN |
PED – 97/23 EC, CRN |
Material certificate EN 10204 3.1 |
On request |
On request |
Pipe and flange certificate available as option |
Ex approvals |
ATEX 2G D sensor
- DN 15 ... 300: EEx d e ia IIC T4 - T6
- DN 350...2000 EEx e ia IIC T4 - T6
Non ATEX sensors
- FM Class 1 Div 2
- CSA Class 1, Div 2
|
ATEX 2G D sensor
- DN 15 ... 300: EEx d e ia IIC T3 - T6
Non ATEX sensors
- FM Class 1 Div 2
- CSA Class 1, Div 2
|
ATEX 2G D sensor
- DN 15 ... 300: EEx d e ia IIC T3 - T6
Non ATEX sensors
- FM Class 1 Div 2
- CSA Class 1, Div 2
|
Drinking water approvals |
EPDM lining:
- WRAS (WRc, BS6920 cold water, GB)
- ACS listed (F)
- DVGW W270 (D)
- Belaqua (B)
|
|
|
Custody transfer (CT) (≤ DN2000) (only together with MAG 5000/6000 CT), order as special |
Cold water pattern approval – DANAK TS 22.36.001, PTB (Denmark and Germany)
Heat meter pattern approval – OIML R 75 (Denmark)
Hot water pattern approval – PTB (Germany)
Other media than water – OIML R 117 (Denmark) |
Cold water pattern approval – DANAK TS 22.36.001, PTB (Denmark and Germany)
Heat meter pattern approval – OIML R 75 (Denmark)
Hot water pattern approval – PTB (Germany)
Other media than water – OIML R 117 (Denmark) |
Cold water pattern approval – DANAK TS 22.36.001, PTB (Denmark and Germany)
Heat meter pattern approval – OIML R 75 (Denmark)
Hot water pattern approval – PTB (Germany)
Other media than water – OIML R 117 (Denmark) |