TRANG CHỦ GIỚI THIỆU
HỆ THỐNG QUẢN LÝ TUYỂN DỤNG LIÊN HỆ
 
Previous
DANH MỤC SẢN PHẨM
Liên Kết Web Site
Lượt Truy Cập
   SẢN PHẨM: 
MAG 3100



Mã sản phẩm: 7ME6310/7ME6340
Tên sản phẩm: MAG 3100

The SITRANS F M MAG 3100 is an electromagnetic flow sensor in a large variety that meets the demands of almost every flow application.

 

Version

MAG 3100

MAG 3100 HT (High Temperature)

MAG 3100 P

Nominal size

DN 15 ... DN 2000 (½” ... 78“)

DN 15…DN 300 (½“ ... 12“)

DN 15…DN 300 (½“ ... 12“)

Measuring principle

electromagnetic induction

electromagnetic induction

electromagnetic induction

Excitation frequency

  • DN 15 ... 65 (½“ … 2½”): 12.5 Hz
  • DN 80 ... 150 (3” ... 6”): 6.25 Hz
  • DN 200 ... 1200 (8” ... 48”): 3.125 Hz
  • DN 1400 ... 2000 (54” ... 78”): 1.5625 Hz
  • DN 15 ... 65 (½“ … 2½”): 12.5 Hz
  • DN 80 ... 150 (3” ... 6”): 6.25 Hz
  • DN 200 ... 300 (8” ... 12”): 3.125 Hz
  • DN 15 ... 65 (½“ … 2½”): 12.5 Hz
  • DN 80 ... 150 (3” ... 6”): 6.25 Hz
  • DN 200 ... 300 (8” ... 12”): 3.125 Hz

Process connection

Flanges

EN 1092-1, raised face (EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions)

  • DN 65 ... 2000 (2½“ … 48”): PN 6 (87 psi)
  • DN 200 ... 2000 (8“ … 48“):PN 10 (145 psi)
  • DN 65 ... 2000 (2½“ … 78“): PN 16 (232 psi)
  • DN 200 ... 600 (8“ … 24”): PN 25 (362 psi)
  • DN 15 ... 600 (½“ … 24”): PN 40 (580 psi)
  • DN 50 ... 300 (2“ … 12“): PN 63 (913 psi)
  • DN 25 ... 300 (1“ … 12“): PN 100 (1450 psi)

ANSI B16.5 (~BS 1560), raised face

  • ½” ... 24”: Class 150 (20 bar (290 psi))
  • ½” ... 24”: Class 300 (50 bar (725 psi))

AWWA C-207, flat face 28” ... 78”: Class D (10 bar)

AS 2129, raised face ½” ... 48”: Table E

AS 4087, raised face:

  • PN 16 (DN 50 ... 1200, 16 bar (232 psi))
  • PN 21 (DN 50 ... 600, 21 bar (304 psi))
  • PN 35 (DN 50 ... 600, 35 bar (508 psi))

Other flanges and pressure ratings on request

EN 1092-1, raised face (EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions)

  • DN 15 ... 300 (½“ … 12”): PN 40 (580 psi)
  • DN 65 ... 300 (2½“ … 12”):PN 16 (232 psi)
  • DN 200 ... 300 (8“ … 12“):PN 10 (145 psi)
  • DN 200 ... 300 (8“ … 12”): PN 25 (362 psi)

ANSI B16.5 (~BS 1560), raised face:

  • ½” ... 12”: Class 150 (20 bar (290 psi))
  • ½” ... 12”: Class 300 (50 bar (725 psi))

AS 2129, raised face ½” ... 12”: Table E

Other flanges and pressure ratings on request

EN 1092-1, raised face (EN 1092-1, DIN 2501 & BS 4504 have the same mating dimensions)

  • DN 15 ... 50 (½“ … 2”): PN 40 (580 psi)
  • DN 65 ... 300 (2½“ … 12”):PN 16 (232 psi)
  • DN 200 ... 300 (8“ … 12“):PN 10 (145 psi)

ANSI B16.5 (~BS 1560), raised face

  • ½” ... 12”: Class 150 (20 bar (290 psi))

Rated operation conditions

Ambient temperature (conditions also dependent on liner characteristiques)

     

Sensor

-40 … +100 ºC (-40 … +212 °F)

-40 … +100 ºC (-40 … +212 °F)

-40 … +100 ºC (-40 … +212 °F)

  • Sensor ATEX

-20 … +60 ºC (-4 … +140 °F)

For up to 150 °C (302 °F) temperature of medium: -20 … +60 ºC (-4 … +140 °F)

For 150 … 180 °C (302 … 356 °F) temperature of medium: -20 … +50 ºC (-4 … +122 °F)

-20 … +60 ºC (-4 … +140 °F)

  • With compact transmitter MAG 5000/6000

-20 … +50 ºC
(-4 … +122 °F)

-20 … +50 ºC
(-4 … +122 °F)

-20 … +50 ºC
(-4 … +122 °F)

  • With compact transmitter MAG 6000 I

-20 … +60 ºC
(-4 … +140 °F)

-20 … +60 ºC
(-4 … +140 °F)

-20 … +60 ºC
(-4 … +140 °F)

  • With compact transmitter MAG 6000 I Ex d

-10 … +60 ºC
(14 … 140 °F)

-10 … +60 ºC
(14 … 140 °F)

-10 … +60 ºC
(14 … 140 °F)

Operating pressure

Operating pressure [abs. bar] (maximum operating pressure decreases with increasing operating temperature and with stainless steel flanges)

  • Neoprene 0.01 ... 100 bar
  • (0.15 ... 1450 psi)
  • EPDM 0.01 ... 40 bar (0.15 ... 580 psi)
  • Linatex® 0.01 ... 40 bar (0.15 ... 580 psi)
  • Ebonite 0.01 ... 100 bar
    (0.15 ... 1450 psi)
  • PTFE (DN ≤ 300, 0.3 … 50 bar/
    ≤ 12“, 4 … 725 psi)
    (350 ≤ DN ≤ 600/14“≤ DN ≤ 24“)
    0.3 ... 40 bar (4 ... 580 psi)
  • PFA
    • DN 25 ... 100 (1“ … 4”): 0.01 ... 50 bar (0.15 ... 725 psi)
  • PTFE Teflon
    • DN 15 ... 300 (½“ … 12”) (130/180 °C (266 °F/356ºF)): 0.3/0.6 ... 50 bar
      (4/8 ... 725 psi) (180 ºC (356 ºF) PTFE has factory mounted grounding SS rings type E & SS terminal box)
  • PFA
    • DN 25 ... 100 (1“ … 4”): 0.01 ... 50 bar (0.15 ... 725 psi)
  • PTFE Teflon
    • DN 15 ... 300 (½“ … 12”): 0.3 ... 50 bar (4 ... 725 psi)
  • PFA
    • DN 15 ... 100 (1“ … 4”): 0.01 ... 50 bar (0.15 ... 725 psi)

Enclosure rating

IP67/NEMA 4X/6 to EN 60529, 1 mH2O for 30 min

Option: IP68/NEMA 6P to EN 60529,10 mH2O cont. (no ATEX)

IP67/NEMA 4X/6 to EN 60529, 1 mH2O for 30 min

Option: IP68/NEMA 6P to EN 60529,10 mH2O cont. (no ATEX)

IP67/NEMA 4X/6 to EN 60529, 1 mH2O for 30 min

Option: IP68/NEMA 6P to EN 60529,10 mH2O cont. (no ATEX)

Pressure drop at 3 m/s

As straigth pipe

As straigth pipe

As straigth pipe

Test pressure

1.5 x PN (where applicable)

1.5 x PN (where applicable)

1.5 x PN (where applicable)

Mechanical load

  • 18 ... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
  • Sensor: 3.17 grms
  • Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms
  • Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 grms
  • 18 ... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
  • Sensor: 3.17 grms
  • Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms
  • Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 grms
  • 18 ... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
  • Sensor: 3.17 grms
  • Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms
  • Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 grms

Temperature of medium

  • Neoprene 0 … +70 °C (32 … 158 °F)
  • EPDM -10 … +70 °C (+14 … +158 °F)
  • Linatex® (rubber) -40 … +70 °C
    (-40 … +158 °F) (for temperatures below
    -20 °C (-4 °F) AISI 304 or 316 flanges must be used)
  • Ebonite 0 … 95 °C (32 … 203 °F)
  • PTFE -20 … +100 °C (-4 … +212 °F)
  • PFA -20 … +100 °C (-4 … +212°F)
  • PTFE -20 … +130 °C (-4 … +266 °F)
  • PTFE -20 … +180 °C (-4 ... +356 °F) Factory mounted grounding rings type E and SS terminal box. Can only be used with remote transmitter.
  • PFA -20 … +150 °C (-4 … +300 °F)

PTFE -20 … +130 °C (-4 … +266 °F)

PFA -20 … +150 °C (-4 … +300 ºF)

EMC

89/336 ECC

89/336 ECC

89/336 ECC

Design

Weight

See dimensional drawings

Flange and housing material

Carbon steel ASTM A 105, with corrosion resistant two component epoxy coating (min. 150 mm) (PN 16 Non PED in size DN 700 ... 2000: Mild Steel)

or

AISI 304 (1.4301) flanges and carbon steel housing, with corrosion resistant two component epoxy coating (min. 150 mm)

or

AISI 316 L (1.4404) flanges and housing, polished

Carbon steel ASTM A 105, with corrosion resistant two component epoxy coating (min. 150 mm)

or

AISI 304 (1.4301) flanges and carbon steel housing, with corrosion resistant two component epoxy coating (min. 150 mm)

or

AISI 316 L (1.4404) flanges and housing, polished

Carbon steel ASTM A 105, with corrosion resistant two component epoxy coating (min. 150 mm)

Measuring pipe material

AISI 304 (1.4301)
(AISI 316L (1.4404) flanges and housing, polished has measuring pipe of AISI 316L (1.4435))

AISI 304 (1.4301)
(AISI 316L (1.4404) flanges and housing, polished has measuring pipe of AISI 316L (1.4435))

AISI 304 (1.4301)

Electrode material

  • AISI 316 Ti (1.4571)
  • Hastelloy C276 (PFA: Hastelloy C22)
  • Platinum/Iridium,
  • Titanium
  • Tantalum
  • AISI 316 Ti (1.4571)
  • Hastelloy C276 (PFA: Hastelloy C22)
  • Platinum/Iridium,
  • Titanium
  • Tantalum

Hastelloy C276 (PFA: Hastelloy C22)

Grounding Electrode material

Material as measuring electrodes: Exceptions - see ordering data

No grounding electrodes

No grounding electrodes

Terminal box (remote version only)

  • Standard Fibre glass-reinforced polyamide
  • Option Stainless steel AISI 316 (1.4436)
  • Ex ATEX (remote version only) Stainless steel AISI 316 (1.4436)
  • Stainless steel AISI 316 (1.4436)
  • Ex ATEX (remote version only) Stainless steel AISI 316 (1.4436)
  • Standard Fibre glass-reinforced polyamide
  • Option Stainless steel AISI 316 (1.4436)
  • Ex ATEX (remote version only) Stainless steel AISI 316 (1.4436)

Cable entries

  • Remote installation 2xM20 or 2x½ NPT
  • Compact installation
    • MAG 5000/MAG 6000: 4xM20 or 4x½”NPT
    • MAG 6000 I: 2xM25(for supply/output)
    • MAG 6000I Ex. d: 2xM20 (for supply/output)
  • Remote installation 2xM20 or 2x½ NPT
  • Remote installation 2xM20 or 2x½ NPT
  • Compact installation
    • MAG 5000/MAG 6000: 4xM20 or 4x½”NPT
    • MAG 6000 I: 2xM25(for supply/output)

MAG 6000I Ex. d: 2xM20 (for supply/output)

Certificates and approvals

Conforms to

PED – 97/23 EC, CRN

PED – 97/23 EC, CRN

PED – 97/23 EC, CRN

Material certificate EN 10204 3.1

On request

On request

Pipe and flange certificate available as option

Ex approvals

ATEX 2G D sensor

  • DN 15 ... 300: EEx d e ia IIC T4 - T6
  • DN 350...2000 EEx e ia IIC T4 - T6

Non ATEX sensors

  • FM Class 1 Div 2
  • CSA Class 1, Div 2

ATEX 2G D sensor

  • DN 15 ... 300: EEx d e ia IIC T3 - T6

Non ATEX sensors

  • FM Class 1 Div 2
  • CSA Class 1, Div 2

ATEX 2G D sensor

  • DN 15 ... 300: EEx d e ia IIC T3 - T6

Non ATEX sensors

  • FM Class 1 Div 2
  • CSA Class 1, Div 2

Drinking water approvals

EPDM lining:

  • WRAS (WRc, BS6920 cold water, GB)
  • ACS listed (F)
  • DVGW W270 (D)
  • Belaqua (B)
   

Custody transfer (CT) (≤ DN2000) (only together with MAG 5000/6000 CT), order as special

Cold water pattern approval – DANAK TS 22.36.001, PTB (Denmark and Germany)

Heat meter pattern approval – OIML R 75 (Denmark)

Hot water pattern approval – PTB (Germany)

Other media than water – OIML R 117 (Denmark)

Cold water pattern approval – DANAK TS 22.36.001, PTB (Denmark and Germany)

Heat meter pattern approval – OIML R 75 (Denmark)

Hot water pattern approval – PTB (Germany)

Other media than water – OIML R 117 (Denmark)

Cold water pattern approval – DANAK TS 22.36.001, PTB (Denmark and Germany)

Heat meter pattern approval – OIML R 75 (Denmark)

Hot water pattern approval – PTB (Germany)

Other media than water – OIML R 117 (Denmark)


For technical specification for transmitter - please see transmitter pages

 

Share |
Video clips
Tin tức mới
Các giấy chứng nhận
Hỗ trợ trực tuyến
Sales Support
0901 185 205
    Support via Yahoo Messanger    
Technical Support
0938 77 40 99
    Support via Yahoo Messanger    
 
Công ty TNHH An Thịnh Tự Động
Trụ sở chính: 186/15 Phan Văn Trị, P.12, Q.Bình Thạnh, TP.HCM
VPGD: 26/1 Nguyễn Bỉnh Khiêm, P. Đa Kao, Q.1, TP HCM
Tel:(84) 28 3910 3379         Fax: (84) 28 3910 3378         Email: info@anthinh.com.vn