Mã sản phẩm:
7ME6140
Tên sản phẩm:
MAG 1100 F
|
The electromagnetic sensor SITRANS F M MAG 1100 F is designed to meet applications in the food and beverage industry.
|
Measuring principle |
Electromagnetic induction |
Excitation frequency |
DN 10 ... 65 (¼“ … 2½”): 12.5 Hz DN 80 ... 100 (3”, 4”): 6.25 Hz |
Process connection |
|
Nominal size |
DN 10 … DN 100 (3/8" … 4") |
Process connection |
Hygienic adapters available for:
- Direct welding onto pipe
- Clamp fitting
- Threaded fitting
|
Rated operating conditions |
|
Ambient conditions |
|
Ambient temperature1) |
|
|
-40 … +100°C (-40 … +212 °F) |
|
-20 … +60°C (-4 … +140 °F) |
- Compact transmitter MAG 5000/6000
|
-20 … +50°C (-4 … +122 °F) |
|
-20 … +60°C (-4 … +140 °F) |
- Compact transmitter MAG 6000 I Ex d
|
-10 … +60°C (+14 … +140 °F) |
Temperature of medium |
|
MAG 1100 F (Ceramic) |
-20 … +150 °C (-4 … +300 °F) Suitable for steam sterilization |
MAG 1100 F (PFA) |
-30 … +130 °C (-20 … +270 °F) Suitable for steam steralization at 150 °C (300 °F) |
Temperature shock |
|
MAG 1100 F |
|
- Duration ≤ 1 min, followed by 10 min rest
|
- DN 10, 15, 25: Max. ΔT ≤ 80 °C/min
(3/8”, ½”, 1”: Max. ΔT ≤ 80 K/min)
- DN 40, 50, 65: Max. ΔT ≤ 70 °C/min
(1½”, 2”, 2½”: Max. ΔT ≤ 70 K/min)
- DN 80, 100: Max. ΔT ≤ 60 °C/min
(3”, 4”: Max. ΔT ≤ 60 K/min) |
MAG 1100 F (PFA) |
Max. ±100 °C (210 °F) momentarily |
Operating pressure |
|
MAG 1100 F (Ceramic) |
- DN 10 ... 65: 40 bar (3/8” … 2½”: 580 psi)
- DN 80: 37.5 bar (3”: 540 psi)
- DN 100: 30 bar (4”: 435 psi)
Vacuum: 1 x 10-6 barabs-5 psiabs) (1.5 x 10 |
MAG 1100 F (PFA) |
20 bar (290 psi)
Vacuum: 0.02 barabs (0.3 psiabs) |
Mechanical load |
18 ... 1 000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
Sensor: 3.17 grms
Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms
Sensor with compact MAG 6000 I/MAG 6000 I Ex mounted transmitter: 1.14 grms
For compact installation with the MAG 6000 I/MAG 6000 I Ex, transmitter to be supported to avoid tension on sensor part. |
Enclosure rating |
|
|
IP67 to EN 60529 (NEMA 4X), 1 mH2O for 30 min |
|
IP68 to EN 60529 (NEMA 6), 10 mH2O cont. |
EMC |
89/336 EEC |
Design |
|
Weight |
See Dimensional drawings |
Material |
|
Enclosure |
|
|
Stainless steel AISI 316L (1.4404) |
Terminal box (remote version only) |
|
|
Fibre glass-reinforced polyamide |
|
Stainless steel AISI 316 (1.4436) |
- Ex ATEX (remote version only)
|
Stainless steel AISI 316 (1.4436) |
Liner |
|
MAG 1100 F (Ceramic) |
Aluminium oxide Al2O3 (ceramics) |
MAG 1100 F (PFA) |
Reinforced PFA (teflon) (no ATEX) |
Electrodes |
|
MAG 1100 F (Ceramic) |
Platinum with gold / Titanium brazing alloy |
MAG 1100 F (PFA) |
- DN 10 ... 15 (3/8” … ½”): Hastelloy C276
- DN 25 … 100 (1” … 4”): Hastelloy C22
|
Cable entries |
- Remote installation 2 x M20 or 2x½ NPT
- Compact installation
- MAG 5000/MAG 6000: 4 x M20 or 4 x ½”NPT
- MAG 6000I: 2 x M25(for supply/output)
- MAG 6000I Ex. d: 2 x M20 (for supply/output)
|
Certificates and approvals |
|
MAG 1100 F (Ceramic) |
3A (sensor with Polyamid terminal box ), transmitter not part of the approval |
- Ex ATEX approvals for sensor or compact with Mag 6000 I Ex
|
ATEX 2G D sensor EEx d e ia IIB T3 - T6 |
- Sensor with/without MAG 5000/6000/ 6000 I
|
CSA/FM Class 1 div 2 |
MAG 1100 F (PFA) |
3A (sensor with Polyamid terminal box ) , transmitter not part of the approval
CSA/FM Class 1 div 2 |
Conforms to |
PED – 97/23/EC and CRN (PFA)
FDA |
1) Conditions are also dependent on liner characteristics
Accessories
Weld-in adapter |
|
Adapter for welding onto dairy pipe |
Tri-Clover ISO 2037, DIN 11850, SMS 3008, BS 4825‑1 |
- DN 10, 15, 25, 40, 50, 65 and 80 (3/8”, ½”, 1”, 1½”, 2”, 2½” and 3”)
|
PN 40 (600 psi) |
|
PN 25 (350 psi) |
Clamp adapter |
Tri-Clamp, ISO 2852, DIN 32676, SMS 3016, BS 4825‑3 |
DN 10, 15, 25, 40 and 50 (3/8”, ½”, 1”, 1½”, and 2”) |
PN 16 (200 psi) |
DN 65, 80 and 100 (2½”, 3” and 4”) |
PN 10 (150 psi) |
Thread adapter |
|
DIN 1181 |
|
- DN 10, 15, 25, and 40 (3/8”, ½”, 1”, and 1½”)
|
PN 40 (600 psi) |
- DN 50, 65, 80 and 100 (2”, 2½”, 3” and 4”)
|
PN 25 (350 psi) |
ISO 2853, BS 4825-4 |
|
- DN 10, 15, 25, 40, 50, 65 and 80 (3/8”, ½”, 1”, 1½”, 2”, 2½ and 3”)
|
PN 16 (200 psi) |
SMS 1145 |
|
- DN 25, 40, 50, 65 and 80 (1”, 1½”, 2”, 2½” and 3”)
|
PN 6 (80 psi) |
Design |
|
Material |
|
Adapter |
Stainless steel AISI 316/Stainless steel AISI 304 (ISO 2852) |
Gasket |
|
|
FKM/FPM with stainless steel insert (AISI 304) (-20 ... +150 °C (-4 ... +302 °F)) |
|
EPDM (-20 ... +150 °C (-4 ... +302 °F))
NBR (-20 ... +100 °C (-4 ... +212 °F)) |
Note:
When combined sensor and adapter, the operating pressure is the lower rated of the pair.
|
|