Mã sản phẩm:
7ME4110
Tên sản phẩm:
MASS 6000 IP67 compact/remote
|
MASS 6000 is based on the latest developments within digital signal processing technology – engineered for high performance, fast flow step response
|
Transmitter SITRANS F C MASSFLO MASS 6000 Compact IP67/NEMA 4X |
Measurement of |
Mass flow [kg/s (lbs/min)], volume flow [l/s (gpm)], fraction [%], °Brix, density [kg/m3, (lbs/ft3)], temperature [°C (°F)] |
Current output |
|
|
0 ... 20 mA or 4 ... 20 mA |
|
< 800 Ω |
|
0 ... 99.9 s adjustable |
Digital output |
|
|
0 ... 10 kHz, 50% duty cycle |
|
0 ... 99.9 s adjustable |
|
24 V DC, 30 mA, 1 KΩ ≤ Rload ≤ 10 KΩ, short-circuit-protected |
|
3 ... 30 V DC, max. 110 mA, 1 KΩ ≤ Rload ≤ 10 KΩ |
Relay |
|
|
Change-over relay |
|
42 V/2 A peak |
|
Error level, error number, limit, flow direction |
Digital input |
11 ... 30 V DC (Ri = 13.6 KΩ) |
|
Start/hold/continue batch, zero point adjust, reset totalizer 1/2, force output, freeze output |
Galvanic isolation |
All inputs and outputs are galvanically isolated, isolation voltage 500 V |
Cut-off |
|
|
0 ... 9.9 % of maximum flow |
Limit function |
Mass flow, volume flow, fraction, density, sensor temperature |
Totalizer |
Two eight-digit counters for forward, net or reverse flow |
Display |
- Background illumination with alphanumerical text, 3 × 20 characters to indicate flow rate, totalized values, settings and faults. Time constant as current output 1
- Reverse flow indicated by negative sign
|
Zero point adjustment |
Manual via keypad or remote via digital input |
Ambient temperature |
|
|
-20 ... +50 °C (-4 ... +122 °F), max. rel. humidity 80% to 31 °C (87.8 °F) decreasing to 50% at 40 °C (104 °F) according to IEC/EN/UL 61010-1 |
|
-40 ... +70 °C (-4 ... +158 °F) (Humidity max. 95 %) |
Communication |
Add-on modules: HART, PROFIBUS PA & DP, MODBUS RTU RS 485, DeviceNet, FOUNDATION Fieldbus H1 |
Enclosure |
|
|
Fibre glass-reinforced polyamide |
|
IP67/NEMA 4X to IEC 529 and DIN 40050 (1 m w.g. for 30 min.) |
|
18 ... 1000 Hz random, 3.17G rms, in all directions, to IEC 68-2-36 |
Supply voltage |
|
24 V version |
|
|
24 V DC/AC, 50 ... 60 Hz |
|
18 ... 30 V DC 20 ... 30 V AC |
|
10 W |
230 V version |
|
|
87 ... 253 V AC, 50 ... 60 Hz |
|
26 VA |
Fuse |
|
|
T400 mA, T 250 V (IEC 127) - Not to be changed by user |
|
T1 A, T 250 V (IEC 127) - Not to be changed by user |
EMC performance |
|
|
EN/IEC 61000-6-4 (Industry) |
|
EN/IEC 61000-6-2 (Industry) |
NAMUR |
Within the value limits according to "Allgemeine Anforderung" with error criteria A in accordance with NE 21 |
Environment |
|
- Environmental conditions acc. to IEC/EN/UL 61010-1:
|
- Altitude up to 2000 m
- POLLUTION DEGREE 2
|
Maintenance |
The flowmeter has a built-in error log/pending menu which should be inspected on a regular basis |
Cable glands |
Two types of cable gland are available in polyamide in the following dimensions: M20 or ½” NPT |
|
|
|
|
Mã sản phẩm:
7ME4110
Tên sản phẩm:
MASS 6000 for 19" insert/19" wall mounting
|
MASS 6000 is based on the latest developments within digital signal processing technology – engineered for high performance
|
SITRANS F C MASSFLO MASS 6000 19” IP20/NEMA 1 or IP66/NEMA 4 version |
Measurement of |
Mass flow [kg/s (lbs/min)], volume flow [l/s (gpm)], fraction [%], °Brix, density [kg/m33)], temperature [°C (°F)] (lbs/ft |
Current output |
|
|
0 ... 20 mA or 4 ... 20 mA |
|
< 800 Ω |
|
0 ... 99.9 s adjustable |
Digital output |
|
|
0 ... 10 kHz, 50 % duty cycle |
|
0 ... 30 s adjustable |
|
24 V DC, 30 mA, 1 KΩ ≤ Rload ≤ 10 KΩ, short-circuit-protected |
|
3 ... 30 V DC, max. 110 mA, 1 KΩ ≤ Rload ≤ 10 KΩ |
Relay |
|
|
Change-over relay |
|
42 V / 2 A peak |
|
Error level, error number, limit, direction |
Digital input |
11 ... 30 V DC |
|
Start/hold/continue batch, zero point adjust, reset totalizer 1/2, force output, freeze output |
Galvanic isolation |
All inputs and outputs are galvanically isolated, isolation voltage 500 V |
Cut-off |
|
|
0 ... 9.9 % of maximum flow |
Limit function |
Mass flow, volume flow, fraction, density, sensor temperature |
Totalizer |
Two eight-digit counters for forward, net or reverse flow |
Display |
- Background illumination with alphanumerical text, 3 × 20 characters to indicate flow rate, totalized values, settings and faults
- Reverse flow indicated by negative sign
|
Zero point adjustment |
Manual via keypad or remote via digital input |
Ambient temperature |
|
|
-20 ... +50°C (-4 ... +122 °F) |
|
-40 ... +70°C (-40 ... +158 °F) (Humidity max. 95 %) |
Communication |
Add-on modules: HART, PROFIBUS PA and DP, MODBUS RTU RS 485, DeviceNet, FOUNDATION Fieldbus H1 |
Enclosure 19” |
|
|
Aluminium/steel (DIN 41494) |
|
IP20/NEMA 1 to IEC 529 and DIN 40050 (1 m w.g. for 30 min.) |
|
18 ... 1000 Hz random, 3.17G rms, in all directions, to IEC 68-2-36 |
Supply voltage |
- 87 ... 253 V AC +10% ... -10%, 50 ... 60 Hz
- 18 ... 30 V DC or 20 ... 30 V AC
|
Power consumption |
|
|
9 VA max. |
|
6 W IN = 250 mA, IST = 2 A (30 ms) |
EMC performance |
|
|
EN/IEC 61000-6-4 (Industy) |
|
EN/IEC 61000-6-2 (Industy) |
Ex approval |
[EEx ia] IIC, DEMKO 03 ATEX 135251X |
Maintenance |
The flowmeter has a built-in error log/pending menu which should be inspected on a regular basis |
Fuse |
T 400 mA, T 250 V (IEC 127), not replaceable by operator |
Cable |
- Max. 300 m
- C: max. 300 [pF/m]; LC/RC: max. 100 [μH/Ω]
- The total cable capacity must be max. 200 nF
|
Cable glands |
The cable gland is available in polyamide, in dimension: PG 13.5 |
|
|
|
|
|
|
Sales Support |
|
0901 185 205 |
|
|
|